TMI industrial piping and installation

GRP tanks & vessels / GRP pour le stockage industriel

TMI designs and manufactures composite equipment for industrial fluid storage and process applications, with particular attention to corrosive environments and the constraints specific to each installation.

Composite storage & process equipment

A tank is designed first around the fluid and its environment

An industrial tank is more than a volume. Resin selection, geometry, nozzles, mechanical loads, integrated equipment and operating conditions directly influence the design.

GRP / FRP tanks and vessels are produced by reinforcing a resin matrix with glass fibres. TMI uses this technology to manufacture equipment with good chemical and mechanical resistance, particularly for corrosive-fluid storage and demanding industrial applications.

The range currently presented by TMI can reach capacities of up to 120 m³. Certain configurations can also be engineered for pressure applications or to accommodate agitators, mixers and other external loads, subject to technical project validation.

Custom design

An industrial tank designed as complete equipment

Usable volume is only a starting point. Filling, draining, agitation, access, support and transport conditions must be considered from the engineering stage.

Depending on requirements, TMI can incorporate the elements needed to operate the tank: nozzles, flanges, manholes, supports, reinforcements, connections and special fittings. This approach prepares the equipment in line with the process and actual site constraints.

  • Vertical or horizontal tanks and vessels according to the project
  • Nozzles, flanges and process connections
  • Manholes, access points and inspection equipment
  • Supports, reinforcements and fastening interfaces
  • Preparation for agitators, mixers or external loads according to engineering
Industrial GRP tank project prepared by TMI
Engineering & fabricationEquipment defined according to the fluid, volume, process and installation constraints.
Industrial applications

Storage solutions for demanding environments

GRP / FRP tanks are particularly relevant when chemical resistance and corrosion control are key design criteria.

01

Chemical & fertilizer industry

Storage and related equipment for acidic solutions and various fluids used in chemical processes.

02

Chlorine industry

Applications involving caustic soda, hypochlorites, brine and other corrosive process fluids.

03

Water treatment

Preparation, treatment or storage tanks integrated into industrial-water and wastewater facilities.

04

Seawater desalination

Equipment for filtration, chemical-cleaning and brine circuits, as well as the various treatment stages.

Transport of a large industrial tank
From engineering to installation

Plan fabrication, transport and installation from the start

For large equipment, project success also depends on how the tank will be handled, transported and positioned on site.

01
Definition of service conditions

Fluid, volume, temperature, possible pressure, environment and operating constraints.

02
Engineering & design

Geometry, connections, reinforcements and interfaces defined in line with requirements.

03
Fabrication & inspection

Manufacture of the equipment in the TMI workshop according to the items validated for the project.

04
Transport & installation

Shipment preparation and on-site intervention according to the agreed scope.

Frequently asked questions

GRP / FRP tanks: key points to clarify before design

The right choice depends primarily on the stored fluid, volume, service conditions and installation environment.

Why use a GRP / FRP tank for corrosive fluids?

GRP / FRP combines a resin matrix with glass fibres. This construction provides chemical and mechanical resistance suited to many corrosion-exposed industrial applications.

What capacity can a TMI GRP / FRP tank reach?

The range currently presented by TMI can reach a capacity of 120 m³. Final capacity and geometry nevertheless depend on the fluid, service conditions and project constraints.

Can a composite tank accommodate an agitator or mixer?

Yes. Certain configurations can be engineered to accommodate an agitator, mixer or other external loads. These loads must be considered during design to correctly define reinforcements and interfaces.

Can GRP / FRP tanks be used for pressure applications?

TMI indicates that certain configurations may be suitable for pressure applications. Suitability must be confirmed case by case through technical engineering based on actual operating conditions.

Can TMI handle tank transport and installation?

Yes. Depending on project scope, TMI can handle shipment preparation, transport and installation work at the customer’s site.

Installation industrielle TMI
Your project de stockage

Do you have a GRP / FRP tank or vessel to size?

Tell us the fluid, required volume and main service conditions. The TMI team can engineer a solution adapted to your installation.